rirtracker

LACNIC daily reports · ← 2016-10-25 · 2016-10-27 →

LACNIC: changes on 2016-10-26

Source

LACNIC publishes no daily list of changes. These come from its transfer log and from comparing its daily statistics:

Before
2016-10-25
After
2016-10-26

Counts

Deregistered
6
Registered
8
Transfer log
1
Confirmed
1
Strong inference
13
Observed only
1
Conflicting
0

What happened

Apparent new issuance
8
Removed
6
Intra-LACNIC transfer
1

In the transfer log (1)

2016-10-26 LACNIC 201.190.128.0/17 Transfer log Intra-LACNIC transfer Confirmed
Transfer log
Transfer: Panamaserver.com (LACNIC) to Arlink S.A. (LACNIC)
From
Panamaserver.com LACNIC
To
Arlink S.A. LACNIC
Inventory
No effect on LACNIC applicant inventory

LACNIC's transfer log records a transfer from Panamaserver.com (LACNIC) to Arlink S.A. (LACNIC) on 2016-10-26 11:00 UTC. The registration changed hands; it is not a new allocation from LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Transfer log Transfer log: RESOURCE_TRANSFER on 2016-10-26 11:00 UTC, Panamaserver.com (LACNIC) to Arlink S.A. (LACNIC); resources moved: 201.190.128.0/17 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: allocated (dated 2011-03-17) source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: allocated (dated 2011-03-17) source · retrieved

Found in LACNIC's statistics (14)

2016-10-26 LACNIC AS28290 − Deregistered Removed (return, revocation or reclamation not publicly distinguishable) Strong inference
Statistics
AS28290 allocated on 2016-10-25, reserved on 2016-10-26
Inventory
Possible future reissue candidate after hold

Removed from active registration. The tracker found it by comparing LACNIC's daily statistics. LACNIC's statistics show it allocated (dated 2007-05-18) on 2016-10-25 and reserved on 2016-10-26. Public sources do not distinguish a voluntary return, revocation, or reclamation. LACNIC publishes no fixed period for which it holds returned ASNs before reissuing them, so the tracker gives no estimate. This does not confirm availability.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: AS28290 allocated on 2016-10-25, reserved on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: allocated (dated 2007-05-18) source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: reserved source · retrieved
2016-10-26 LACNIC AS61909 − Deregistered Removed (return, revocation or reclamation not publicly distinguishable) Strong inference
Statistics
AS61909 allocated on 2016-10-25, reserved on 2016-10-26
Inventory
Possible future reissue candidate after hold

Removed from active registration. The tracker found it by comparing LACNIC's daily statistics. LACNIC's statistics show it allocated (dated 2014-04-29) on 2016-10-25 and reserved on 2016-10-26. Public sources do not distinguish a voluntary return, revocation, or reclamation. LACNIC publishes no fixed period for which it holds returned ASNs before reissuing them, so the tracker gives no estimate. This does not confirm availability.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: AS61909 allocated on 2016-10-25, reserved on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: allocated (dated 2014-04-29) source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: reserved source · retrieved
2016-10-26 LACNIC 189.36.240.0/20 − Deregistered Removed (return, revocation or reclamation not publicly distinguishable) Strong inference
Statistics
189.36.240.0/20 allocated on 2016-10-25, reserved on 2016-10-26
Inventory
Possible future reissue candidate after hold

Removed from active registration. The tracker found it by comparing LACNIC's daily statistics. LACNIC's statistics show it allocated (dated 2007-05-18) on 2016-10-25 and reserved on 2016-10-26. Public sources do not distinguish a voluntary return, revocation, or reclamation. LACNIC's current hold for IPv4 space applies to removals from 2020-03-01 on, and this one came earlier, so the tracker gives no estimate. This does not confirm availability.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 189.36.240.0/20 allocated on 2016-10-25, reserved on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: allocated (dated 2007-05-18) source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: reserved source · retrieved
2016-10-26 LACNIC 191.52.208.0/20 − Deregistered Removed (return, revocation or reclamation not publicly distinguishable) Strong inference
Statistics
191.52.208.0/20 allocated on 2016-10-25, reserved on 2016-10-26
Inventory
Possible future reissue candidate after hold

Removed from active registration. The tracker found it by comparing LACNIC's daily statistics. LACNIC's statistics show it allocated (dated 2014-04-29) on 2016-10-25 and reserved on 2016-10-26. Public sources do not distinguish a voluntary return, revocation, or reclamation. LACNIC's current hold for IPv4 space applies to removals from 2020-03-01 on, and this one came earlier, so the tracker gives no estimate. This does not confirm availability.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 191.52.208.0/20 allocated on 2016-10-25, reserved on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: allocated (dated 2014-04-29) source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: reserved source · retrieved
2016-10-26 LACNIC 200.33.175.0/24 − Deregistered Removed (return, revocation or reclamation not publicly distinguishable) Observed only
Statistics
200.33.175.0/24 assigned on 2016-10-25, reserved on 2016-10-26
Inventory
Possible future reissue candidate after hold

Removed from active registration. The tracker found it by comparing LACNIC's daily statistics. LACNIC's statistics show it assigned (dated 2016-10-25) on 2016-10-25 and reserved on 2016-10-26. Public sources do not distinguish a voluntary return, revocation, or reclamation. LACNIC's current hold for IPv4 space applies to removals from 2020-03-01 on, and this one came earlier, so the tracker gives no estimate. This does not confirm availability. Another change to this range was reported the day before or after (2016-10-25: Added 200.33.175.0/24), so the before-and-after statistics may include it.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 200.33.175.0/24 assigned on 2016-10-25, reserved on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: assigned (dated 2016-10-25) source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: reserved source · retrieved
2016-10-26 LACNIC 2804:16ac::/32 − Deregistered Removed (return, revocation or reclamation not publicly distinguishable) Strong inference
Statistics
2804:16ac::/32 allocated on 2016-10-25, reserved on 2016-10-26
Inventory
Possible future reissue candidate after hold

Removed from active registration. The tracker found it by comparing LACNIC's daily statistics. LACNIC's statistics show it allocated (dated 2014-04-29) on 2016-10-25 and reserved on 2016-10-26. Public sources do not distinguish a voluntary return, revocation, or reclamation. LACNIC publishes no fixed period for which it holds returned IPv6 space before reissuing it, so the tracker gives no estimate. This does not confirm availability.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 2804:16ac::/32 allocated on 2016-10-25, reserved on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: allocated (dated 2014-04-29) source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: reserved source · retrieved
2016-10-26 LACNIC AS266322 + Registered Apparent new issuance Strong inference
Statistics
AS266322 available on 2016-10-25, allocated on 2016-10-26
Inventory
Likely issued from LACNIC-controlled inventory

No transfer record matches. LACNIC's statistics show it available on 2016-10-25 and allocated (dated 2016-10-26) on 2016-10-26. It moved from LACNIC's unissued pool to an active registration dated around that day, so it appears to be newly issued by LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: AS266322 available on 2016-10-25, allocated on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: available source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: allocated (dated 2016-10-26) source · retrieved
2016-10-26 LACNIC AS266323 + Registered Apparent new issuance Strong inference
Statistics
AS266323 available on 2016-10-25, allocated on 2016-10-26
Inventory
Likely issued from LACNIC-controlled inventory

No transfer record matches. LACNIC's statistics show it available on 2016-10-25 and allocated (dated 2016-10-26) on 2016-10-26. It moved from LACNIC's unissued pool to an active registration dated around that day, so it appears to be newly issued by LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: AS266323 available on 2016-10-25, allocated on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: available source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: allocated (dated 2016-10-26) source · retrieved
2016-10-26 LACNIC 170.238.120.0/22 + Registered Apparent new issuance Strong inference
Statistics
170.238.120.0/22 reserved on 2016-10-25, allocated on 2016-10-26
Inventory
Likely issued from LACNIC-controlled inventory

No transfer record matches. LACNIC's statistics show it reserved on 2016-10-25 and allocated (dated 2016-10-26) on 2016-10-26. It moved from LACNIC's unissued pool to an active registration dated around that day, so it appears to be newly issued by LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 170.238.120.0/22 reserved on 2016-10-25, allocated on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: reserved source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: allocated (dated 2016-10-26) source · retrieved
2016-10-26 LACNIC 170.238.156.0/22 + Registered Apparent new issuance Strong inference
Statistics
170.238.156.0/22 available on 2016-10-25, allocated on 2016-10-26
Inventory
Likely issued from LACNIC-controlled inventory

No transfer record matches. LACNIC's statistics show it available on 2016-10-25 and allocated (dated 2016-10-26) on 2016-10-26. It moved from LACNIC's unissued pool to an active registration dated around that day, so it appears to be newly issued by LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 170.238.156.0/22 available on 2016-10-25, allocated on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: available source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: allocated (dated 2016-10-26) source · retrieved
2016-10-26 LACNIC 170.238.170.0/23 + Registered Apparent new issuance Strong inference
Statistics
170.238.170.0/23 available on 2016-10-25, assigned on 2016-10-26
Inventory
Likely issued from LACNIC-controlled inventory

No transfer record matches. LACNIC's statistics show it available on 2016-10-25 and assigned (dated 2016-10-26) on 2016-10-26. It moved from LACNIC's unissued pool to an active registration dated around that day, so it appears to be newly issued by LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 170.238.170.0/23 available on 2016-10-25, assigned on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: available source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: assigned (dated 2016-10-26) source · retrieved
2016-10-26 LACNIC 170.238.240.0/22 + Registered Apparent new issuance Strong inference
Statistics
170.238.240.0/22 available on 2016-10-25, allocated on 2016-10-26
Inventory
Likely issued from LACNIC-controlled inventory

No transfer record matches. LACNIC's statistics show it available on 2016-10-25 and allocated (dated 2016-10-26) on 2016-10-26. It moved from LACNIC's unissued pool to an active registration dated around that day, so it appears to be newly issued by LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 170.238.240.0/22 available on 2016-10-25, allocated on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: available source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: allocated (dated 2016-10-26) source · retrieved
2016-10-26 LACNIC 2804:3608::/32 + Registered Apparent new issuance Strong inference
Statistics
2804:3608::/32 available on 2016-10-25, allocated on 2016-10-26
Inventory
Likely issued from LACNIC-controlled inventory

No transfer record matches. LACNIC's statistics show it available on 2016-10-25 and allocated (dated 2016-10-26) on 2016-10-26. It moved from LACNIC's unissued pool to an active registration dated around that day, so it appears to be newly issued by LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 2804:3608::/32 available on 2016-10-25, allocated on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: available source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: allocated (dated 2016-10-26) source · retrieved
2016-10-26 LACNIC 2804:360c::/32 + Registered Apparent new issuance Strong inference
Statistics
2804:360c::/32 available on 2016-10-25, allocated on 2016-10-26
Inventory
Likely issued from LACNIC-controlled inventory

No transfer record matches. LACNIC's statistics show it available on 2016-10-25 and allocated (dated 2016-10-26) on 2016-10-26. It moved from LACNIC's unissued pool to an active registration dated around that day, so it appears to be newly issued by LACNIC.

Evidence (3) · classifier 1.4.0,
  1. Statistics Found by comparing LACNIC's daily statistics: 2804:360c::/32 available on 2016-10-25, allocated on 2016-10-26 source · retrieved
  2. Before LACNIC delegated statistics 2016-10-25, before the change: available source · retrieved
  3. After LACNIC delegated statistics 2016-10-26, after the change: allocated (dated 2016-10-26) source · retrieved